| Parameter | Waarde |
|---|---|
| Item | Specifications |
| Product | FP7 High-speed Counter Units |
| Onderdeelnummer | AFP7HSC2T |
| Productnaam | FP7 High-speed Counter |
| Productnummer | AFP7HSC2T |
| Invoer: Isolatiemethode | Photocoupler insulation |
| Ingang: Nominale ingangsspanning | 12 to 24 V DC / 3.5 to 5 V DC |
| Telfunctie: Tellertype | Linear counter / Ring counter |
| Telfunctie: Externe I/O | Control signal input: 4 points (2 points/ch), External output: 4 points (2 points/ch) |
| Telfunctie: Ingangssignaal | Phases A, B and Z |
| Ingang: Ingangsimpedantie: 5 V DC | 390 Ohm (5 V DC) approx. |
| Telfunctie: Telbereik | Signed 32-bit (-2,147,483,648 to +2,147,483,647) |
| Ingang: Ingangsimpedantie: 24 V DC | 3.0 kOhm approx. |
| Telfunctie: Aantal tellers | 2ch |
| Ingang: Gebruiksspanningsbereik: 5 V DC | 3.5 to 5.25 V DC |
| Overige functies: Vastlegfunctie | Acquires the current count value from the edges of input signals, and stores it in the capture 0 register or capture 1 register. The value of the specified capture register will be overwritten by a new value and the old value will be discarded every time a counter value is captured. |
| Telfunctie: Teller invoertype | Individual input (Phases A and B): 1 multiple, 2-multipleDirection discrimination input: 1 multiple, 2-multiple2-phase input: 1 multiple, 2-multiple, 4-multiple |
| Invoer: Instelling van de tijdconstante | None, 0.1 micro s, 0.2 micro s, 0.5 micro s, 1.0 micro s, 2.0 micro s and 10.0 micro s |
| Ingang: Gebruiksspanningsbereik: 24 V DC | 10.8 to 26.4 V DC |
| Telfunctie: Maximale invoerfrequentie | 4 MHz / 8 MHz for individual input (phases A and B) (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz for direction discrimination input (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz /16 MHz for 2-phase input (Duty ratio 50 plus or minus 10 %, Phase shifting below 5 %) |
| Overige functies: Interrupt-ingangsfunctie | Available (2 points/ch, Max. 8 points/unit)(Note) The interrupt input function can be used for 8 points per unit and for a maximum of 8 units (max. 64 points) in the whole system. However, the entire scan time slows down as more interrupt programs are used. Minimize the use of interrupt programs.(Note) The priority order for interrupt inputs is as follows; In a unit, from the smallest interrupt bit. In the whole system, from the smallest unit number. |
| Ingang: Minimale inschakelspanning / Minimale inschakelstroom: 5 V DC | 3.0 V DC / 4 mA |
| Vergelijkingsfunctie: Doelwaarde-overeenkomstfunctie | Depending on the count direction, sets or resets the output when the counter value reaches the target value. |
| Ingang: Minimale inschakelspanning / Minimale inschakelstroom: 24 V DC | 10 V DC / 4 mA |
| Ingang: Maximale uitschakelspanning / Maximale uitschakelstroom: 5 V DC | 1.0 V DC / 0.5 mA |
| Externe uitvoer: Uitvoerfunctie voor vergelijkingsresultaten | Outputs the result of comparison function. |
| Ingang: Maximale uitschakelspanning / Maximale uitschakelstroom: 24 V DC | 2.0 V DC / 2 mA |
| Meetfunctie: Frequentiemeting | Measures the intervals between the variations of count values, and calculates the frequency. |
Technische specificaties en prestatiegegevens
Installatie- en bedieningshandleiding