| Parameter | Waarde |
|---|---|
| NPN | - |
| COM3 | E3S-DCP21-IL3 |
| Item | Sensing method |
| Lens | Methacrylic resin (PMMA) |
| Model | E3S-DCP21-IL2 |
| Uitvoer | Push-pull |
| Knoppen | Elastomers |
| Baudrate | E3S-DCP21-IL3: COM3 (230.4 kbps), E3S-DCP21-IL2: COM2 (38.4 kbps) |
| Connector | Diecast zinc (nickel-plated brass) |
| Materialen | Case |
| Indicatoren | ABS |
| Gegevenslengte | PD size: 8 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) |
| Reactietijd | Operate or reset: 50 µs max. for each (2-point teaching mode)Operate or reset: 150 µs max. for each (1-point teaching mode) |
| Detectiemethode | Appearance |
| Afstand waarnemen | 10±3 mm (White paper 10 ×10 mm) |
| Minimale cyclustijd | E3S-DCP21-IL3 (COM3): 1.5 ms, E3S-DCP21-IL2 (COM2): 4.8 ms |
| Beveiligingscircuits | Power supply reverse polarity protection, output short-circuit protection and output incorrect connection protection |
| Beschermingsgraad | IEC 60529 IP67 |
| Voedingsspanning | 10 to 30 VDC±10% (Ripple (p-p) 10% max.) |
| Belangrijkste IO-Link-functies | Operation mode switching between NO and NCTimer function of the control output and timer time selecting function (Select a function from disabled, ON delay, OFF delay, one-shot or ON/OFF delay.) (Select a timer time of 1-5000 ms.)Selecting function of ON delay timer time for instability (0 (disabled)-1000 ms)Monitor output function (PD output indicating a relative detection quantity)Energizing time read-out function (unit: h)Initialize the settings function “Restore the factory settings” |
| Omgevingstemperatuurbereik | Operating: −10 to 55°C; Storage: −25 to 70°C (with no icing or condensation) |
| Lichtbron (golflengte) | Red LED (635 nm), Green LED (525 nm), Blue LED (465 nm) |
| Spotgrootte (referentiewaarde) | 1 × 4 mm |
| Communicatiespecificaties | IO-Link specification |
| Diffuus-reflecterend (merkdetectie) |
Technische specificaties en prestatiegegevens