| Parameter | Waarde |
|---|---|
| 18 V DC ... 32 V DC | |
| Samensmelten | electronic |
| Opmerking | No. 14 |
| Type | DIN rail module, one-piece |
| Kleur | black (RAL 9005) |
| Diepte | 80 mm |
| Breedte | 12.5 mm |
| Hoogte | 83 mm |
| Algemeen | When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted. |
| Spanning | < 3 V DC (Low state) |
| Zekeringtype | Automatic device |
| Schakel uit | typ. 1.8 x IN |
| Producttype | Device circuit breakers |
| Pulsduur | min. 10 ms |
| Schroefdraad | M4 |
| Spanningsval | 130 mV (at IN) |
| Vochtigheidstest | 96 h, 95 % RH, 40 °C |
| Ingangsspanning | max. 32 V DC |
| Montagetype | DIN rail: 35 mm |
| Uitgangsstroom | max. 0.2 A (Short-circuit-proof) |
| Uitgangsspanning | 24 V DC |
| Productfamilie | EC-E |
| Verbindingsnaam | Auxiliary contact |
| Hoogte NS 35/15 | 90.5 mm |
| Aantal kanalen | 1 |
| Inschakelvertraging | typ. 0.5 s |
| Triggermethode | E (electronic) |
| Artikelrevisie | 02 |
| Hoogte NS 35/7,5 | 83 mm |
| Striplengte | 10 mm |
| Verbindingsmethode | Screw connection |
| Dwarsdoorsnede AWG | 26 ... 6 (converted acc. to IEC) |
| Bedrijfsspanning | 24 V DC |
| Aanhaalmoment | ... 1.2 Nm |
| Nominale stroom IN | 6 A |
| Schakelfunctie | Reset input |
| Huidig verbruik | typ. 2.6 mA (at 24 V DC) |
| Mate van vervuiling | 2 |
| Diëlektrische sterkte | max. 32 V DC (Load circuit) |
| Aantal posities | 1 |
| Nominale overspanningsspanning | 0.5 kV |
| Beschermingsgraad | IP20 (Housing) |
| Maximale capacitieve belasting | 20000 µF |
| Vereiste reservezekering | not required, integrated failsafe element |
| Nominale doorsnede | 16.00 mm² |
| Schakelcapaciteit ICN | Active current limitation |
| Normen/specificaties | UL 508 |
| Actieve stroombeperking | active |
| MTBF (IEC 61709, SN 29500) | 7430000 h (at 25 °C with 80 % load) |
| Geleiderdoorsnede AWG | 20 ... 6 |
| Geleiderdoorsnede stijf | 0.5 mm² ... 16 mm² |
| Omgevingstemperatuur (bedrijfstemperatuur) | 0 °C ... 50 °C (non-condensing) |
| Stroombereik in gesloten circuit I0 | typ. 25 mA ±5 mA (When switched on) |
| Flexibele doorsnede van de geleider | 0.5 mm² ... 16 mm² |
| Brandbaarheidsclassificatie volgens UL 94 | V0 |
| Omgevingstemperatuur (opslag/transport) | -20 °C ... 70 °C |
| Doorsnede van een flexibele geleider [AWG] | 20 ... 6 (converted acc. to IEC) |
| 2 geleiders met dezelfde doorsnede, massief | 0.5 mm² ... 4 mm² |
| 2 geleiders met dezelfde doorsnede, flexibel | 0.5 mm² ... 4 mm² |
| 2 geleiders met dezelfde doorsnede AWG stijf | 20 ... 12 (converted acc. to IEC) |
| 2 geleiders met dezelfde doorsnede AWG flexibel | 20 ... 12 (converted acc. to IEC) |
| Flexibele geleiderdoorsnede (ferrule met plastic huls) | 0.5 mm² ... 10 mm² |
| Flexibele geleiderdoorsnede (ferrule zonder plastic huls) | 0.5 mm² ... 10 mm² |
| Geleiderdoorsnede, flexibel, met adereindhuls, met plastic huls | 0.5 mm² ... 10 mm² |
| Flexibele geleiderdoorsnede, met ferrule zonder plastic huls. | 0.5 mm² ... 10 mm² |
| 2 geleiders met dezelfde doorsnede, flexibel, met adereindhuls zonder plastic huls | 0.5 mm² ... 2.5 mm² |
| 2 geleiders met dezelfde doorsnede, flexibel, met TWIN-aderhuls met kunststof huls | 0.5 mm² ... 6 mm² |