| Parameter | Waarde |
|---|---|
| Diepte | 35.6 mm |
| Breedte | 15.7 mm |
| Hoogte | 71 mm |
| Algemeen | They should not be used to separate SELV/PELV electrical circuits from other electrical circuits, as safe separation is not guaranteed. |
| Isolatie | Basic Insulation |
| Certificaat | CE Compliance |
| Producttype | Relay socket |
| Productfamilie | ESSENTIAL edition |
| Piekcategorie | Ii |
| Verbindingstype | Fork Terminal |
| Testspanning () | 1 kVEff(50 Hz, 1 min., open contact) |
| Beschermingsindex | IP20 |
| Type montage | Rail mounting |
| Aanhaalmoment | 1 Nm |
| Mate van vervuiling | 2 |
| AWG-geleidersectie | 21 ... 16 |
| Positie voor montage | discretionary |
| Stijf geleidergedeelte | 0.4 mm² ... 1.5 mm² |
| Nominale ingangsspanning UN | ≤ 230 V AC |
| Normen/Specificaties | IEC 60664-1 |
| Installatie-instructies | Alignable without separation |
| Dimensionering van de isolatiespanning | 250 V AC |
| Flexibel geleidergedeelte | 0.4 mm² ... 1.5 mm² |
| Omgevingstemperatuur (gebruikstemperatuur) | -40 °C ... 70 °C |
| Dimensionering van transiënte spanning | 2.5 kV |
| Testspanning (wikkeling/contact) | 4 kVEff(50 Hz, 1 min., winding/contact) |
| Omgevingstemperatuur (Opslag/Transport) | -40 °C ... 70 °C |
Technische specificaties en prestatiegegevens