| Parameter | Waarde |
|---|---|
| (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW PLUS 961 EO/EW PLUS 961 EO LVD |
| D. I (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Model (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW PLUS 971 EO |
| Voeding (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 230V~ ±10% 50/60Hz |
| Formaat (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | Panel 74x32 |
| Sondes (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 2 NTC |
| Relais (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 2 |
| Display (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | with decimal point * 3 digits + sign |
| Kopieerkaart (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Precisie (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | better than 0.5% of end of scale + 1 digit |
| Referentie (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW29DIEXC4780 |
| Afmetingen (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 74 x 32 x 59 mm |
| Resolutie (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 or 0.1°C |
| Verbruik (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 4.5 W max |
| USB Unicard (thermostaat met detectie van over- en onderspanning (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Connectiviteit (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | Port TTL for connection to Unicard/Copy Card or to system monitoring TelevisSystem (need Bus Adapter) |
| Analoge ingangen (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 NTC |
| Digitale ingang (thermostaat met detectie van over- en onderspanning (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Weergaveveld (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | probe NTC: -50,0...110,0°C |
| Energiebesparing (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Voedingsspanning (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 230VAC |
| Digitale uitgangen (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 SPST: 2Hp (12FLA - 72LRA) max 240V |
| Veldmeting (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | -50,0...110,0°C |
| Configureerbare ingangen (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 digital (SELV)1 digital (SELV) / serial TTL* |
| Verpakkingsfabrikant (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| * selecteerbaar via parameter (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | |
| Detectie van onderspanning (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | No / Yes (only model LVD) |
| EO: Milieugeoptimaliseerd (THERMOSTAAT MET DETECTIE VAN OVERSPANNING EN ONDERSPANNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
Technische specificaties en prestatiegegevens
Installatie- en bedieningshandleiding