| Parameter | Waarde |
|---|---|
| 134 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| MTTF | 293 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Diepte | 115 mm |
| Invoer | ± 2.2 kV |
| Breedte | 23 mm |
| Hoogte | ≤ 2000 m |
| Signaal | Ethernet |
| Spanning | 10 V |
| Opmerkingen | Criterion B |
| Materiaal | PA 6.6-FR |
| Netspanningstype | Permanent line |
| Certificaat | CE-compliant |
| Criterium A | Normal operating behavior within the specified limits. |
| Criterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Uitgangsvermogen | ≤ 91 W (With PoL) |
| Producttype | Ethernet extenders |
| Montagetype | DIN rail mounting |
| Identificatie | ISA-S71.04-1985 G3 Harsh Group A |
| Geluidsemissie | EN 61000-6-4, Class A, industrial area of application |
| Geluidsimmuniteit | EN 55035 |
| Basisfuncties | Gigabit Ethernet extender in accordance with ITU G.9960 |
| Veldintensiteit | 10 V/m |
| Frequentiebereik | 80 MHz ... 3 GHz (80% amplitude modulation with 1 kHz) |
| Aantal kanalen | 1 |
| Ontlading in de lucht | ± 8 kV |
| Vervuilingsgraad | 2 |
| Striplengte | 10 mm |
| Verbindingsmethode | Push-in spring connection |
| Contactontlading | ± 6 kV |
| Dwarsdoorsnede AWG | (converted acc. to IEC) |
| Montagepositie | Vertical (horizontal DIN rail) |
| Stroomverbruik | ≤ 7.5 W (Without PoL, without PoE) |
| Indirecte afvoer | ± 6 kV |
| Beveiligingscircuit | Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode |
| Transmissiesnelheid | ≤ 1000 Mbps (Depending on the quality of the data line) |
| Maattekening | |
| Ondersteunde protocollen | Protocol-transparent for TCP/IP, IPv4, and IPv6 |
| Transmissielengte | < 100 m (shielded twisted pair) |
| Transmissiemethode | QAM (quadrature amplitude modulation) carrier frequency method |
| Beschermingsgraad | IP20 |
| Elektrische isolatie | VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE |
| Maximaal uitgangsvermogen | 15 W (at ≤55°C) |
| Voedingsspanningsbereik | 18 V DC ... 57 V DC |
| Montage-instructies | To allow for air circulation, mount the device freestanding, with a clearance of at least one centimeter on all sides to other devices. |
| Normen/voorschriften | EN 61000-4-2 |
| Nominale voedingsspanning | 24 V DC (Without PoL, without PoE) |
| Seriële transmissiesnelheid | 10/100/1000 Mbps |
| Elektromagnetische compatibiliteit | Conformance with EMC Directive 2014/30/EU |
| Omgevingstemperatuur (bedrijfstemperatuur) | -40 °C ... 60 °C (Free standing, without PoE) |
| Toegestane luchtvochtigheid (tijdens gebruik) | 10 % ... 95 % (non-condensing) |
| Enkelvoudige draad/aansluitpunt, flexibel | 0.2 mm² ... 2.5 mm² |
| Brandbaarheidsclassificatie volgens UL 94 | V0 |
| Enkele geleider/aansluitpunt, stijf | 0.2 mm² ... 2.5 mm² |
| Omgevingstemperatuur (opslag/transport) | -40 °C ... 85 °C |
| Doorsnede van een flexibele geleider [AWG] | 24 ... 16 |
| Toegestane luchtvochtigheid (opslag/transport) | 10 % ... 95 % (non-condensing) |
| Testspanningsdata-interface/voeding | 1.5 kV AC (50 Hz, 1 min.) |
| Geleiderdoorsnede, flexibel, met adereindhuls, met plastic huls | 0.2 mm² ... 2.5 mm² |
| Flexibele geleiderdoorsnede, met ferrule zonder plastic huls. | 0.2 mm² ... 2.5 mm² |
| 2 geleiders met dezelfde doorsnede, flexibel, met TWIN-aderhuls met kunststof huls | 0.5 mm² ... 1.5 mm² |
Technische specificaties en prestatiegegevens
Installatie- en bedieningshandleiding