| Parameter | Waarde |
|---|---|
| PoDL Power Class 11 | |
| MTTF | 185.12 Years (SN 29500 standard, temperature 25 °C, duty cycle 21%) |
| Diepte | 119 mm |
| Breedte | 45 mm |
| Hoogte | 130 mm |
| Algemeen | Telephone and on-site support (for a fee) |
| Beheer | Web-based management (HTTP/HTTPS) |
| Ontslag | MRP (Media Redundancy Protocol) |
| Signaal-LED's | Data Receiving, Link Status |
| Bouw | Sample book |
| Producttype | Switch |
| Signaalvertraging | ≥ 1.9 μs (Store-and-Forward mode, 10/100/1000 MBit/s, depending on frame size) |
| Testspanning | 500 V DC |
| Havenbeveiliging | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Productfamilie | Managed Switch 2000 |
| Schelpmateriaal | Fiber-reinforced polycarbonate |
| Voedingsspanning | 20 V DC ... 32 V DC |
| Verbindingstype | RJ45 |
| Lokale diagnose | US1/2 Supply Voltage US1, US2 Green LED |
| Overige functies | MMS & GOOSE Transmission (IEC 61850-8-1) |
| Restrimpel | 3.6 VPP(within the permissible voltage range) |
| Afmetingsschema | |
| Filterfuncties | Quality of Service (8 priority classes) |
| Stroomaansluiting | via COMBICON, max. conductor cross-section 1.5 mm² |
| Beschermingsindex | IP20 |
| Bijzondere kenmerken | Extended temperature range, Single Pair Ethernet ports with PoDL |
| Type montage | Rail mounting |
| MAC-adrestabel | 8k |
| Stroomverbruik | 65 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
| Statusindicatie | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Verificatiepad | 1 minute at FE 500 V DC |
| Soort bescherming | III (VDE 0106) |
| Aantal kanalen | 3 (RJ45 ports) |
| Transmissiesnelheid | 10/100/1000 MBit/s |
| Basisfunctionaliteit | Switch Store and Forward, IEEE 802.3 compliant |
| Mate van vervuiling | 2 |
| IP-parameterisatie | DHCP-Client |
| Voedingsspanning (gelijkstroom) | 24 V DC (Simultaneous PoDL power supply according to IEEE 802.3cg) |
| Transmissielengte | 100 m (per segment) |
| Transmissiemedium | copper |
| Trilling (service) | according to IEC 60068-2-6: 5g, 150 Hz |
| Storingen (tijdens gebruik) | 30g (EN 60068-2-27) |
| Diagnostische functies | RMON History |
| Tijdsynchronisatie | SNTP (Simple Network Time Protocol) |
| Transmissiefysica | copper |
| AWG-geleidersectie | 24 ... 16 |
| Interferentie-emissie | EN 61000-6-4 |
| Luchtdruk (Service) | 80 kPa ... 110 kPa up to 2000 m above sea level (No derating) |
| Interferentieweerstand | EN 61000-6-2 |
| Stijf geleidergedeelte | 0.25 mm² ... 1.5 mm² |
| Lengte die moet worden ontdaan van isolatie | 9 mm |
| PROFINET conformiteitsklasse | Conformance-Class B |
| Flexibel geleidergedeelte | 0.25 mm² ... 1.5 mm² |
| Maximale stroomabsorptie | 2.2 A (Us= Min, TAMB= Max, SPE = 8x max. PoDL Power, 100% data traffic on all connected ports) |
| Typische stroomabsorptie | 1.03 A (to Us= Nom, TAMB= 25°C, SPE = 4x max. PoDL Power, 100% data traffic on all connected ports) |
| Omgevingstemperatuur (gebruikstemperatuur) | -40 °C ... 70 °C |
| Elektromagnetische compatibiliteit | Compliance with EMC Directive 2014/30/EU |
| Naleving van EMC-richtlijnen | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Opmerking over het verbindingstype | Autonegoation and Autocrossing |
| Functie van de PROFINET-module | PROFINET Device |
| Luchtdruk (Opslag/Transport) | 79 kPa ... 108 kPa up to 2000 m above sea level (No derating) |
| Status en diagnostische indicaties | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Toegestane luchtvochtigheid (service) | 10 % ... 95% (non-condensing) |
| Omgevingstemperatuur (Opslag/Transport) | -40 °C ... 85 °C |
| Toegestane luchtvochtigheid (opslag/transport) | 10 % ... 95% (non-condensing) |
| Vrij van storende stoffen die de vernis bevochtigen. | Yes |
| Maximaal gedissipeerd vermogen onder nominale omstandigheden | 12 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
Technische specificaties en prestatiegegevens
Installatie- en bedieningshandleiding