| Parameter | Waarde |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| rood | IDC/FLK50 (5) = IDC/FLK14-1 (3) |
| blauw | IDC/FLK50 (9) = IDC/FLK14-1 (7) |
| grijs | IDC/FLK50 (1) = IDC/FLK14-1 (9) |
| Toonhoogte | 2.54 mm |
| zwart | IDC/FLK50 (3) = IDC/FLK14-1 (1) |
| bruin | IDC/FLK50 (4) = IDC/FLK14-1 (2) |
| groente | IDC/FLK50 (8) = IDC/FLK14-1 (6) |
| wit | IDC/FLK50 (11) = IDC/FLK14-1 (10) |
| oranje | IDC/FLK50 (6) = IDC/FLK14-1 (4) |
| violet | IDC/FLK50 (10) = IDC/FLK14-1 (8) |
| geel | IDC/FLK50 (7) = IDC/FLK14-1 (5) |
| Hoogte | ≤ 2000 m |
| Afgeschermd | no |
| Kabeltype | 14X0.14 [PVC] |
| wit-zwart | IDC/FLK50 (2) = IDC/FLK14-1 (11) |
| witbruin | IDC/FLK50 (12) = IDC/FLK14-1 (12) |
| Kabellengte | 2.5 m |
| Halogeenvrij | no |
| Producttype | System cable |
| UL AWM-stijl | 2464/1061 |
| Geleidertype | Round cable set |
| AWG-signaallijn | 26 |
| Artikelrevisie | 06 |
| Kabelweerstand | ≤ 145 Ω/km (20 °C) |
| Vlamvertragendheid | IEC 60332-1-2 (raw cable) |
| Verbindingsmethode | IDC/FLK socket strip |
| Weerstand tegen olie | can withstand occasional splashes (raw cable) |
| Geschikte I/O-kaart | 6ES7521-1BL10-0AA0 |
| Geleidermateriaal | Tin-plated Cu litz wires |
| Opmerkingen over de werking | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Aantal posities | 14 |
| Beschermingsgraad | IP00 |
| Isolatieweerstand | ≥ 20 MΩ*km (20 °C) |
| Aantal verbindingen | 1 |
| Buitenmantel, kleur | gray |
| Nominale bedrijfsmodus | 100% operating factor |
| Bedrijfsspanning (wisselstroom) | ≤ 30 V AC |
| Bedrijfsspanning (gelijkstroom) | ≤ 60 V DC |
| Buitenmantel, materiaal | Semi-rigid PVC |
| Dwarsdoorsnede van een geleider | 14x 0.14 mm² |
| Buitendiameter van de kabel | 6.40 mm ±0.4 mm |
| Stroomsterkte (per pad, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Stroomsterkte (per pad, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Inbreng-/onttrekkingscycli | > 50 |
| Draaddiameter inclusief isolatie | 1 mm ±0.03 mm |
| Omgevingstemperatuur (bedrijfstemperatuur) | -40 °C ... 70 °C (fixed installation) |
| Geleiderstructuur signaallijn | 7x 0.16 mm |
| Dynamisch draagvermogen (buiging) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Aansluiting conform standaard | based on IEC 60603-13 |
| Omgevingstemperatuur (opslag/transport) | -40 °C ... 80 °C |
| Kleinste buigradius, vaste installatie | 55 mm |
| Beschermingsgraad (Installatielocatie) | ≥ IP54 (Installation location) |
| Kleinste buigradius, verplaatsbare installatie | 104 mm |
Technische specificaties en prestatiegegevens