| Parameter | Waarde |
|---|---|
| B48 | |
| SCCR | 5 kA (UL 2237) |
| Type | B24 |
| Tests | DIN VDE 0627/86 |
| Breedte | 34 mm |
| Hoogte | 32.8 mm |
| Lengte | 110.5 mm |
| Serie | HC-D |
| Algemeen | For HC-D64 housing, crimp contacts CK1,6-ED (crimp contacts not included in scope of supply) |
| Sollicitatie | Signal |
| Producttype | Contact insert with a fixed no. of positions |
| Montage-instructies | To ensure correct use, installation in housing with IP54 protection or better is required |
| Nominale huidige waarde | 10 A |
| Artikelrevisie | 12 |
| Contactdiameter | 1.6 mm |
| Contactmateriaal | Copper alloy |
| Aanhaalmoment | 0.8 Nm ... 1.2 Nm (PE connection) |
| Verbindingsprofiel | 64+PE |
| Mate van vervuiling | 3 |
| Maattekening | |
| Aantal posities | 64 |
| Nominale overspanningsspanning | 4 kV |
| Overspanningscategorie | III |
| Verbindingstechnologie | Crimp connection |
| Contactmateriaaltype | turned |
| Nominale spanning (III/3) | 250 V |
| Normen/voorschriften | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Dwarsdoorsnede van een geleider | 0.14 mm² ... 2.5 mm² |
| Contactmateriaal van de drager | PC |
| Contactoppervlakmateriaal | Ag (alternatively Au) |
| Noteer het aantal posities | 64+PE |
| Inbreng-/onttrekkingscycli | ≥ 500 |
| Aansluitdoorsnede AWG | 26 ... 14 |
| Omgevingstemperatuur (bedrijfstemperatuur) | -40 °C ... 125 °C (including heating up of contacts) |
| Afstand tussen de boorgaten, horizontaal | 104.5 mm |
| Aansluiting conform standaard | IEC / EN |
| Aantal verbindingen per positie | 1 |
| Bouw- en testvoorschriften | DIN VDE 0627/86 |
| Brandbaarheidsclassificatie volgens UL 94 | V0 |
| Strippen van de individuele draad | 8 mm (0.14 mm² ... 1.5 mm²) |