Belangrijkste specificaties
: Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Breedte: 34.2 mm
Hoogte: 41.8 mm
Lengte: 14.6 mm
Leveranciersinformatie
Producten: 0
Wordt doorgaans binnen 2-3 werkdagen verzonden.
Kwaliteit gegarandeerd
Snelle verzending
Technische ondersteuning

Technische specificaties

Parameter Waarde
Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
Breedte 34.2 mm
Hoogte 41.8 mm
Lengte 14.6 mm
Serie HC-M-02
Algemeen For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required
Sollicitatie Power
Producttype Modular contact insert
Montage-instructies - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage.
Nominale huidige waarde 40 A
Contactmateriaal Copper alloy
Zeshoekige dop SW 2
Contactnummering 1 - 2
Aanhaalmoment 1.5 Nm (2.5 mm² ... 4 mm²)
Verbindingsprofiel 2
Mate van vervuiling 3
Maattekening
Aantal posities 2
Nominale overspanningsspanning 8 kV
Overspanningscategorie III
Verbindingstechnologie Axial screw connection
Nominale spanning (III/3) 1000 V
Aantal module-slots 1
Dwarsdoorsnede van een geleider 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used)
Contactmateriaal van de drager PC
Contactoppervlakmateriaal Ag
Inbreng-/onttrekkingscycli ≥ 500
Aansluitdoorsnede AWG 12 ... 10
Omgevingstemperatuur (bedrijfstemperatuur) -40 °C ... 125 °C
Aansluiting conform standaard IEC / EN
Brandbaarheidsclassificatie volgens UL 94 V0
Strippen van de individuele draad 8 mm +1 mm (for 6 mm²)