| Parameter | Waarde |
|---|---|
| Type | Laser sheet |
| Kleur | aluminum color |
| Breedte | 45 mm |
| Cycli | 2 |
| Lengte | 30 mm |
| Resultaat | Test passed |
| Algemeen | Depending on the actuator or annunciator that requires identification, it may cover the first line of the marking field. Please take this into account when creating the identification. |
| IRM 901 | Test passed |
| IRM 902 | Test passed |
| Materiaal | Aluminum |
| Procedure | A |
| Onderdelen | free from silicone, halogen, and cadmium |
| Producttype | Device marking |
| Vereisten | ≥ 5 N |
| Klimaatniveau | AHT 1.0 S |
| Gatdiameter | 22.50 mm |
| Montagetype | insert |
| Specificatie | DIN EN ISO 1518-1:2019-10 (following) |
| Testduur | 96 h |
| Veegbestendigheid | DIN EN 61010-1 (VDE 0411-1) |
| Materiaalsterkte | 0.80 mm |
| Toepassingsgebied | SIEMENS: Command and signaling devices, Ø 22 mm, SIRIUS ACT |
| Identificatietechnologie | Direct laser marking |
| Beoordeling 225 °C (250 °C) | Test passed |
| Aantal afzonderlijke labels | 15 |
| Omgevingstemperatuur (bedrijfstemperatuur) | -25 °C ... 120 °C (At temperatures above 80 °C there might be a slight change to the material surface) |
| Aanbevolen luchtvochtigheid (opslag/transport) | 50 % |
| Aanbevolen omgevingstemperatuur (opslag/transport) | 23 °C |