| Parameter | Waarde |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| D.w.z | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Item | Specifications |
| Kabel | UL style 2464, No.22 AWG 12-core |
| Gewicht | Approx. 680 g |
| Product | Safety door switch with key |
| Materiaal | Enclosure : PA66 |
| Bescherming | IP 65 (IEC 60529) |
| Onderdeelnummer | SG-B2-K2CC-5 |
| Kabellengte | 5m16.404 ft |
| Productnaam | Safety door switch with key SG-B2 |
| Productnummer | SG-B2-K2CC-5 |
| Vergrendelingskracht | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Schokbestendigheid | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Contactweerstand | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Contactregeling | |
| Bedrijfsfrequentie | 900 operations/hour |
| Toepasselijke normen | EN 1088, IEC 60947-5-1, EN 60947-5-1,GS-ET-19, UL 508, CSA C22.2 No.14 |
| Directe openingskracht | 80 N min. |
| Sleutelverwijderingspositie | C(removable in LOCK position) |
| Trillingsbestendigheid | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Toepasselijke richtlijnen | Machinery directive (2006/42/EC)Low voltage directive (2006/95/EC) |
| Directe reisopening | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| Elektrische duurzaamheid | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| Mechanische duurzaamheid | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| Thermische stroom (Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| Inductieve belasting (AC-15) | - |
| Inductieve belasting (DC-13) | 2.3A |
| Bedrijfssnelheid van de actuator | 0.05 to 1.0 m/sec. |
| Sleutel: Directe openingskracht | 0.6 N・m min. |
| Legenda: Sleutel treksterkte | 1.0 N・m min. |
| Sleutel: Directe opening van een diploma | 60°min. |
| Kernwoord: Mechanische duurzaamheid | 100,000 operations min. |
| Nominale isolatiespanning (Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| Sleutel: Bedrijfsduurzaamheid van de sleutel | 10,000 operations min. |
| Legenda: Bedrijfsspecificaties | 2 positions |
| Bedrijfsomstandigheden: Hoogte | 2,000 m6,561.68 ftmax. |
| Beschermingsklasse tegen elektrische schokken | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Kortsluitingsbeveiligingsinrichting | Use 250 V / 10 A fast acting type fuse |
| Impulsbestendigheidsspanning (Uimp) | 2.5 kV |
| Voorwaardelijke kortsluitstroom | 50 A (250 V) |
| Bedrijfsomstandigheden: Omgevingsvochtigheid | 45 to 85 % RH |
| Bedrijfsomstandigheden: Vervuilingsgraad | 3 (Inside 2) |
| Toepasselijke normen: Gebruiksnormen | IEC 60204-1, EN 60204-1 |
| Bedrijfsomstandigheden: Omgevingstemperatuur | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Nominale bedrijfsspanning (Ue) / Nominale bedrijfsstroom (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |