Openingstijden: maandag tot en met vrijdag van 9:00 tot 18:00 uur.
UERVW - UERVW ERVW ER-VW PANASONIC Ionizer ER-V with two outputs
Op voorraad Populair product

UERVW

UERVW ERVW ER-VW PANASONIC Ionizer ER-V with two outputs

$0.00 USD
4782 op voorraad
Belangrijkste specificaties
Item: Specifications
Gewicht: Net weight: 110 g approx., Gross weight: 180 g approx.
Details: Spot type
Product: Thin-type Ionizer
Leveranciersinformatie
PANASONIC
PANASONIC
Producten: 4316
Wordt doorgaans binnen 2-3 werkdagen verzonden.
Kwaliteit gegarandeerd
Snelle verzending
Technische ondersteuning

Technische specificaties

Parameter Waarde
Item Specifications
Gewicht Net weight: 110 g approx., Gross weight: 180 g approx.
Details Spot type
Product Thin-type Ionizer
Materiaal Enclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten
Accessoires Connector attached cable: 1 pc. (length 0.5 m1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc.
Ionbalans plus or minus10 V or less(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Onderdeelnummer ER-VW
Productnaam Thin-type Ionizer ER-VW
I/O-connector For power & input / output: 8-pin connector, For connection: 9-pin connector
Productnummer ER-VW
Voedingsspanning 24 V DC plus or minus 10 %
Omgevingsvochtigheid 35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH
Toepasselijke vloeistof Air (dried clean air)(Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ℉) and an air filter (mesh size around 0.01 microm0.0004 mil).
Ontladingsmethode High frequency AC method
Ozonproductie 0.05 ppm or less(Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm11.811 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa.
Koppelbare eenheden Maximum number of connectable units: 5 (Including this unit)
Toegevoerde luchtstroom 60 liter/min. (ANR) or less
Luchtdrukbereik 0.05 to 0.5 MPa
Aarding van de behuizing Capacitor earth
Omgevingstemperatuur 0 to +55 ℃+32 to +131 ℉(No dew condensation allowed), Storage: –10 to +65 ℃+14 to +149 ℉
Tijd voor het verwijderen van de kosten 1 sec. or less (plus or minus1,000 V to plus or minus100 V)(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Huidig ​​verbruik 120 mA or less
Ingang resetten (RESET) In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR
Uitvoer: Uitvoerbewerking Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normalError output (ERROR): OFF when abnormal discharge is detected, ON when operation is normalDischarge output (DSC) (Note): ON when discharging, OFF when discharge halts(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Ontladingsuitgangsspanning 2,000 V approx.
Indicatoren: Controleer (CONTROLEER) Orange LED (lights up when the discharge needle is dirty or worn, etc.)
Indicatoren: Fout (ERROR) Red LED (lights up when abnormal discharge is detected)
Indicatoren: Vermogen (POWER) Green LED (lights up when the power is ON)
Indicatoren: Afvoer (DSC) Green LED (lights up when discharging)(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Ontladingsstop-ingang (DSC UIT) Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)(Note:"DSC" is an abbreviated name of "DISCHARGE".)
CE-markering conforme richtlijnen EMC Directive, RoHS Directive
Indicatoren: Luchtmonitoring (AIR) Orange LED (lights up when no air is being supplied)(Note) Discharge halts when lights up.
Uitgang: Kortsluitbeveiliging Incorporated
Uitvoer [Controle (CONTROLE) Fout (FOUT) Ontlading (DSC)] NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current)(Note:"DSC" is an abbreviated name of "DISCHARGE".)

Productbeschrijving

ER-VW ionizer with two ionized air outlets. Incorporates 0.5 m connection cable, end and ground connector
Belangrijkste kenmerken
  • Industriële kwaliteit
  • RoHS-conform
  • CE-gecertificeerd
  • 1 jaar garantie

Productdocumenten

Gegevensblad

Technische specificaties en prestatiegegevens

Gebruikershandleiding

Installatie- en bedieningshandleiding

Top