Belangrijkste specificaties
Item: Specifications
Kabel: 0.09 mm22-core shielded cable, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Details: Sensor heads(Thru-beam type)
Product: Amplifier-separated Type Digital Laser Sensor
Leveranciersinformatie
PANASONIC
PANASONIC
Producten: 4316
Wordt doorgaans binnen 2-3 werkdagen verzonden.
Kwaliteit gegarandeerd
Snelle verzending
Technische ondersteuning

Technische specificaties

Parameter Waarde
Item Specifications
Kabel 0.09 mm22-core shielded cable, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Details Sensor heads(Thru-beam type)
Product Amplifier-separated Type Digital Laser Sensor
Materiaal Enclosure: PBTCover: Acrylic
Accessoire MS-EXL2-2 (Mounting plate): 2 pcs.
Spotgrootte Approx. dia. 5 mm dia. 0.197 in or less (at a distance from the emitter of 1 m 3.281 ft)
Bescherming IP67 (IEC)
Onderdeelnummer LS-H102-C5
Productnaam Amplifier-separated Type Digital Laser Sensor LS-500
Productnummer LS-H102-C5
Waarnemingsobject Opaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Omgevingsvochtigheid 35 to 85 % RH, Storage: 35 to 85 % RH
Schokbestendigheid 98 m / s2acceleration (10 G approx.) in X, Y and Z directions three times each
Detectiebereik: HYPR 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Detectiebereik: U-LG 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Omgevingsverlichting Incandescent light: 3,000 ℓx or less at the light-receiving face
Omgevingstemperatuur -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Bedrijfsindicator Orange LED (lights up when the amplifier output is ON)
Trillingsbestendigheid 10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2in X, Y, and Z direction for 2 hours each.
Toepasselijke versterkers LS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Uitzendend element: Type Red semiconductor laser diode
Isolatieweerstand 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Naleving van wet- en regelgeving EMC Directive, RoHS Directive
Detectiebereik: standaardmodus 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Detectiebereik: SNELLE modus 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Detectiebereik: H-SP-modus 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Detectiebereik: U-LG-modus 1m3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Spanningsbestendigheid 1,000 V AC for one min. between all supply terminals connected together and enclosure
Uitstralend element: Laserklasse Class 1 [IEC / EN / JIS / GB / KS / FDA](Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Uitzendelement: Maximale output 2mW
Emissie-element: Piek-emissiegolflengte 660 nm 0.026 mil

Productbeschrijving

LS500. Sensor head, barrier, side detection, range 1m, cable 5m
Belangrijkste kenmerken
  • Industriële kwaliteit
  • RoHS-conform
  • CE-gecertificeerd
  • 1 jaar garantie

Productdocumenten

Gegevensblad

Technische specificaties en prestatiegegevens

Gebruikershandleiding

Installatie- en bedieningshandleiding

Top