Item: Specifications
Gewicht: Net weight: 190 g approx.Gross weight: 320 g approx.
Product: Safety Control Unit
Materiaal: Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
Leveranciersinformatie
PANASONIC
PANASONIC
Producten: 4316
Wordt doorgaans binnen 2-3 werkdagen verzonden.
Kwaliteit gegarandeerd
Snelle verzending
Technische ondersteuning

Technische specificaties

Parameter Waarde
Item Specifications
Gewicht Net weight: 190 g approx.Gross weight: 320 g approx.
Product Safety Control Unit
Materiaal Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
PFHD/ MTTFD 9.73 x 10−10/ 100 years or more
Onderdeelnummer SF-C21
Kabellengte 100 m328.084 ftor less
Productnaam Safety Control Unit SF-C21
Productnummer SF-C21
Vervuilingsgraad 2
Verbindingsmethode Input / output and power supply: Detachable spring cage termina l blocksRS-485: Detachable spring-cage terminal blockUSB: Mini-B male
Gerelateerde standaarden IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851
Vergrendelingsfunctie Incorporated
Bedrijfshoogte 2,000 m6561.680 ftor less(Note) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level.
Trillingsbestendigheid 5 to 8.4 Hz frequency, 3.5 mm0.138 inhalf amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2(1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6)
Logica-instelfunctie Input mode, control mode, output mode, reset mode, auxiliary ou tput mode
Categorie overspanning II
Uitvoer van de dempingsindicator Semiconductor photo MOS relay output x 1- Maximum load current: 60 mA- Supply voltage: Same as the voltage of the power supply for internal- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Vergrendelingsontgrendelingsfunctie Incorporated
Logische selectiefunctie No.0: Customization controlNo.1: Overall stop controlNo.2: Parallel muting controlNo.3: Sequential muting controlNo.4: Partial stop control 1No.5: Partial stop control 2No.6: Two-hand controlNo.7: OR controlNo.8: Operation mode selection control
Veiligheidsingang (IN1 tot IN8) 2 inputs x 4, Rated voltage: Same as the voltage of the power supply for internal
Toepasselijke normen: EMC IEC 61000-6-2, IEC 61326-3-1, EN 55011
Opstarttijd na inschakelen 2 sec. or less
Toepasselijke normen: Veiligheid IEC 61508-1 to 3, EN 61508-1 to 3 (SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061 (SILCL3), UL 61010-1, UL 61010-2-201, UL 1998
Regeluitgang (OUT1 tot OUT4) PNP open-collector transistor with 2 outputs x 2- Maximum source current: 300 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Communicatiefunctie (MODBUS RTU) Interface: RS-485Protocol: MODBUS RTUMaximum transmission distance: 100 m328.084 ftMaximum number of units that can be connected: 8 units (slaves)
Externe apparaatbewakingsfunctie Incorporated
Veiligheidsingang (IN1 tot IN8): AAN-niveau Input voltage: 18 VInput current: 3.5 mA
Uitgang van de dempingsindicator: Uitgangsmodus ON when muting / override
Veiligheidsingang (IN1 tot IN8): UIT-niveau Input voltage: 5 VInput current: 1.0 mA
Uitvoer van de dempingsindicator: Reactietijd 10 ms or less
Toepasselijke regelgeving en certificeringen CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety)Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, Korea's Radio Waves Act conformity registration
Omgevingsbestendigheid: Omgevingsvochtigheid 30 to 85 % RH, Storage: 30 to 85 % RH
Milieubestendigheid: Schokbestendigheid 147 m/s2(15 G) 11 ms in X, Y and Z directions for three times each (IEC / EN 60068-2-27)
Voedingsspanning: Voeding voor externe apparaten 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Voedingsspanning: Voeding voor interne 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Besturingsuitgang (OUT1 tot OUT4): Uitgangsmodus True: ONFalse: OFF
Veiligheidsingang (IN1 tot IN8): Ingangsimpedantie 4.7 KΩ approx.
Omgevingsbestendigheid: Omgevingstemperatuur -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Regeluitgang (OUT1 tot OUT4): Reactietijd OFF response: 10 ms or lessON response: 100 ms or less
Milieubestendigheid: Mate van bescherming IP20 (IEC)(must be installed in a control panel with protectio n IP54 or higher)
Milieubestendigheid: Isolatiebestendigheid 20 MΩ, or more, with 500 V DC megger(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Stroomverbruik: Voeding voor externe apparaten 100 mA or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Stroomverbruik: Voeding voor interne 200 mA or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Veiligheidsingang (IN1 tot IN8): Nominale ingangsstroom 5 mA approx.
Hulpuitgang (AUX1 tot AUX4) (niet-veiligheidsuitgang) PNP open-collector transistor with 1 output x 4- Maximum source current: 60 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Regeluitgang (OUT1 tot OUT4): AAN-vertragingfunctie Incorporated
Milieubestendigheid: Spanningsbestendigheid 1,000 V AC for one min.(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Regeluitgang (OUT1 tot OUT4): UIT-vertragingsfunctie Incorporated
Uitgang van dempingsindicator: Kortsluitbeveiliging Incorporated
Regeluitgang (OUT1 tot OUT4): Kortsluitbeveiliging Incorporated
Veiligheidsingang (IN1 tot IN8): Duur van de detecteerbare AAN-stand 10 ms or more
Veiligheidsingang (IN1 tot IN8): Duur van de ondetecteerbare UIT-stand 0.7 ms or less
Hulpuitgang (AUX1 tot AUX4) (niet-veiligheidsuitgang): Reactietijd 10 ms or less
Hulpuitgang (AUX1 tot AUX4) (niet-veiligheidsuitgang): Kortsluitbeveiliging Incorporated
Hulpuitgang (AUX1 tot AUX4) (niet-veiligheidsuitgang): Uitgangsmodus (fabrieksinstellingen) AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)AUX3: Reset trigger output (ON under reset release wait condition)AUX4: Lockout output (OFF when lockout)
Hulpuitgang (AUX1 tot AUX4) (niet-veiligheidsuitgang): Uitgangsmodus (elk van de hulpuitgangen kan worden aangepast met behulp van de softwaretool) Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON)Positive logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is ON)Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true)Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true)Reset trigger output (ON under reset release wait condition)Lockout output (OFF when lockout)Muting indicator output (ON when muting / override)Monitor output in response to IN1 to IN8 (ON when input)No output (normally OFF)

Productbeschrijving

Control unit for barriers and other safety products, Cat. 4(Ple) and SIL3, 4 inputs, 2 outputs, 8 pre-established logics according to cat regulations. 4 (Ple) and 1 customizable logic, self-diagnostic
Belangrijkste kenmerken
  • Industriële kwaliteit
  • RoHS-conform
  • CE-gecertificeerd
  • 1 jaar garantie

Productdocumenten

Gegevensblad

Technische specificaties en prestatiegegevens

Gebruikershandleiding

Installatie- en bedieningshandleiding

Top